Motion tracking for medical imaging: a nonvisible structured light tracking approach OV Olesen, RR Paulsen, L Hojgaard, B Roed, R Larsen IEEE transactions on medical imaging 31 (1), 79-87, 2011 | 126 | 2011 |
List-Mode PET Motion Correction Using Markerless Head Tracking: Proof-of-Concept With Scans of Human Subject O Olesen, J Sullivan, T Mulnix, R Paulsen, L Højgaard, B Roed, R Carson, ... Medical Imaging, IEEE Transactions on 32 (2), 200-209, 2013 | 80 | 2013 |
Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction OV Olesen, M Sibomana, SH Keller, F Andersen, J Jensen, S Holm, ... 2009 IEEE nuclear science symposium conference record (NSS/MIC), 3789-3790, 2009 | 60 | 2009 |
Methods for motion correction evaluation using 18F-FDG human brain scans on a high-resolution PET scanner SH Keller, M Sibomana, OV Olesen, C Svarer, S Holm, FL Andersen, ... Journal of Nuclear Medicine 53 (3), 495-504, 2012 | 53 | 2012 |
Quantifying the financial savings of motion correction in brain MRI: a model‐based estimate of the costs arising from patient head motion and potential savings from … JM Slipsager, SL Glimberg, J Søgaard, RR Paulsen, HH Johannesen, ... Journal of Magnetic Resonance Imaging 52 (3), 731-738, 2020 | 42 | 2020 |
Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI JM Slipsager, AH Ellegaard, SL Glimberg, RR Paulsen, MD Tisdall, ... Plos one 14 (4), e0215524, 2019 | 39 | 2019 |
Motion tracking in narrow spaces: a structured light approach OV Olesen, RR Paulsen, L Højgaard, B Roed, R Larsen International Conference on Medical Image Computing and Computer-Assisted …, 2010 | 35 | 2010 |
Comparison of prospective and retrospective motion correction in 3D‐encoded neuroanatomical MRI JM Slipsager, SL Glimberg, L Højgaard, RR Paulsen, P Wighton, ... Magnetic resonance in medicine 87 (2), 629-645, 2022 | 25 | 2022 |
Accurate and simple calibration of DLP projector systems J Wilm, OV Olesen, R Larsen Emerging Digital Micromirror Device Based Systems and Applications VI 8979 …, 2014 | 25 | 2014 |
Structured light 3D tracking system for measuring motions in PET brain imaging OV Olesen, MR Jørgensen, RR Paulsen, L Højgaard, B Roed, R Larsen Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling …, 2010 | 23 | 2010 |
Apparatus and method for motion tracking in brain imaging OV Olesen, R Larsen, RR Paulsen, L Højgaard US Patent 10,542,913, 2020 | 20 | 2020 |
Prospective motion correction for diffusion weighted EPI of the brain using an optical markerless tracker J Berglund, A van Niekerk, H Rydén, T Sprenger, E Avventi, O Norbeck, ... Magnetic Resonance in Medicine 85 (3), 1427-1440, 2021 | 19 | 2021 |
Hybrid PET/MRI imaging in healthy unsedated newborn infants with quantitative rCBF measurements using 15O-water PET JB Andersen, U Lindberg, OV Olesen, D Benoit, CN Ladefoged, ... Journal of Cerebral Blood Flow & Metabolism 39 (5), 782-793, 2019 | 19 | 2019 |
SLStudio: Open-source framework for real-time structured light J Wilm, OV Olesen, R Larsen 2014 4th International Conference on Image Processing Theory, Tools and …, 2014 | 16 | 2014 |
Innovations in pet/ct TL Klausen, SH Keller, OV Olesen, M Aznar, FL Andersen The quarterly journal of nuclear medicine and molecular imaging: official …, 2012 | 13 | 2012 |
Real Time MRI motion correction with markerless tracking C Benjaminsen, RR Jensen, P Wighton, MD Tisdall, HH Johannesen, ... ISMRM 2016 Annual Meeting & Exhibition, 2017 | 11 | 2017 |
New attenuation correction for the HRRT using transmission scatter correction and total variation regularization M Sibomana, SH Keller, C Svarer, OV Olesen, F Andersen, S Holm, ... 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), 3284-3286, 2009 | 10 | 2009 |
An MRI compatible surface scanner OV Olesen, J Wilm, A Van der Kouwe, RR Jensen, R Larsen, LL Wald ISMRM Scientific Workshop 2014: Motion Correction in MRI, 2015 | 9 | 2015 |
A movable phantom design for quantitative evaluation of motion correction studies on high resolution PET scanners OV Olesen, C Svarer, M Sibomana, SH Keller, S Holm, JA Jensen, ... IEEE Transactions on Nuclear Science 57 (3), 1116-1124, 2010 | 9 | 2010 |
Real time surface registration for PET motion tracking J Wilm, OV Olesen, RR Paulsen, L Højgaard, B Roed, R Larsen Image Analysis: 17th Scandinavian Conference, SCIA 2011, Ystad, Sweden, May …, 2011 | 8 | 2011 |